Daikin MC70LPVM Instructions d'exploitation Page 1

Naviguer en ligne ou télécharger Instructions d'exploitation pour Filtres à air Daikin MC70LPVM. Daikin MC70LPVM Operating instructions [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Air Purifi er

Air Purifi erOPERATION MANUALFloor Standing, Wall-hanging TypeMODELMC70LPVM00_CV_3P276413-3C.indd 100_CV_3P276413-3C.indd 1 9/17/2011 6:47:20 PM9

Page 2 - Features

9Preparation before OperationAccessories check Confi rm all the accessories are included.ABCDA: Pleated fi lter…1 sheet< For initial installation &

Page 3 - CONTENTS

10Attach the pleated fi lter. 4 Make sure to set the prefi lter (green) and the pleated fi lter (front: white, rear: blue) in place. If you operate the u

Page 4 - Main unit

11Preparation before OperationInstallation of the unit Installed on a table or the fl oor100cm from ceiling50cm from wall50cm from wallAirfl ow10cm fro

Page 5

12Preparation of remote controller A battery is already set in the remote controller.The remote controller can be used only after pulling out the • c

Page 6

Make sure that the front panel is closed.13How to OperateTo start the operationPress .Operation starts and the airfl ow rate lamp lights up.• When yo

Page 7 - Inside of the unit

14To change the airfl ow manuallyAirfl ow manual operationPress .Each time the button is pressed, the airfl ow rate changes • as follows.“ (Quiet)”“

Page 8 - Unit display

15Quick Reference Table of MaintenanceBefore performing maintenance, stop the unit and disconnect the power plug. (It may cause electric shock or inju

Page 9 - Green Yellow Red

165Pleated fi lter6Deodorising catalyst unit7Main unit or air inlet for sensorPleated fi lterDeodorising catalyst unitFace the white side to the front.D

Page 10 - Preparation before Operation

17Removing and Attaching Each PartRemoveRemove the front panel.1 Push the 2 clips (right and left), and pull the front panel • upward and remove it.Pu

Page 11 - Attach the front panel.7

18Wear rubber gloves to remove and attach the opposing pole plates. Hands can be cut on the opposing pole plates and ionised wires.CAUTIONRemoving and

Page 12

1FeaturesAbout air purifyingThe powerful suction of a high airfl ow rate captures dust, pollen, etc.The purifying capacity improves as the airfl ow rate

Page 13 - Remote controller

UNIT1(Plasma ioniser)UNIT2(Streamer unit)Wear rubbergloves. * Remove dirt from recesses with a cotton swab, etc.2) Ionised wire (8 locations)Remove di

Page 14 - How to Operate

Clean the ionised wires without dislodging them from the V-groove.3) Streamer unitWipe the needles lightly with • a soft piece of cloth such as a cott

Page 15 - To clean pollen

21Time for cleaningWhen the fi lter lamp in the display lights up or blinksIt is not necessary to replace the pleated fi lter until the fi lter lamp ligh

Page 16

ON / OFF / Mode change buttonAirfl ow rate lamp22Sensitivity Setting of the Air Quality Sensor (dust sensor)The sensitivity of the air quality sensor c

Page 17 - Main unit or air inlet

Front panelDeodrising catalyst unitIonised wire23Frequently Asked QuestionsBefore consulting your dealer, check the following points.The air quality s

Page 18

24TroubleshootingBefore consulting your dealer or asking for repairs, check the following points. If the problems still can not be solved, consult you

Page 19

25TroubleshootingBefore consulting your dealer or asking for repairs, check the following points. If the problems still can not be solved, consult you

Page 20 - Cleaning of UNIT1 and UNIT2

26MEMO01_EN_3P276413-3C.indd 2601_EN_3P276413-3C.indd 26 9/27/2011 1:27:43 PM9/27/2011 1:27:43 PM

Page 21 - 3) Streamer unit

3P276413-3C M10B195B(1111) HTTwo-dimensional bar code is a code for manufacturing.00_CV_3P276413-3C.indd 200_CV_3P276413-3C.indd 2 9/17/2011 6:4

Page 22

2What is the “Streamer” function?This function uses a “streamer discharge”, a type of plasma discharge, to generate high-speed electrons with strong o

Page 23 - (dust sensor)

3Safety PrecautionsBefore use, read these Safety Precautions to ensure proper handling of equipment. The precautions used in this manual are classifi

Page 24 - Frequently Asked Questions

4WARNINGMain unitDo not use combustible substances, i.e., hair spray, insecticides, etc., • near the unit. Do not wipe the unit with benzene or thinne

Page 25 - Troubleshooting

5Safety PrecautionsCAUTIONMain unit Do not expose plants or animals to direct air currents from the unit. • Overexposure to air currents may have adve

Page 26

6Name and Operation of Each PartFrontAir inlet for air quality sensor (dust sensor)Air inlet for odour sensorReceiverFront panelModel name / Serial nu

Page 27

7Name and Operation of Each PartRemote controllerPage 13, 14. ►Child proof lock buttonIt prevents small children from mishandling the unit.Brightness

Page 28 - 3P276413-3C M10B195B

8Operation lampTurbo lamp (orange)• Anti-pollen lamp (green)• Sleep mode lamp (green)• Filter lamp (orange)The fi lter lamp lights up when the pleated

Commentaires sur ces manuels