7 English
For programming TEMPERATURE, FAN SPEED
and AIR FLOW DIRECTION, follow the procedure
shown below.
TEMPERATURE SETTING
Press TEMPERATURE SETTING button and
program the setting temperature.
Each time this button is pressed, setting
temperature rises 1°C.
Each time this button is pressed, setting
temperature lowers 1°C.
The setting is impossible for fan operation.
NOTE
The setting temperature range of the remote con-
troller is 16°C to 32°C.
FAN SPEED CONTROL
Press FAN SPEED CONTROL button.
High or Low fan speed can be selected.
The microchip may sometimes control the fan speed
in order to protect the unit.
AIR FLOW DIRECTION ADJUST
There are 2 ways of adjusting the air discharge
angle.
1. A. Up and down adjustment
2. B. Left and right direction
Fig. 1
ADJUSTMENT
A. up and down direction
B. Left and right direction
A. UP AND DOWN DIRECTION
The movable limit of the flap is changeable. Con-
tact your Daikin dealer for details.
Press the AIR FLOW DIRECTION ADJUST
button to select the air direction as shown
below.
The AIR FLOW FLAP display
swings as shown below and the
air flow direction continuously
varies. (Automatic swing set-
ting)
Press AIR FLOW DIRECTION
ADJUST button to select the air
direction of your choice.
The AIR FLOW FLAP display
stops swinging and the air flow
direction is fixed (Fixed air flow
direction setting).
MOVEMENT OF THE AIR FLOW FLAP
For the following conditions, micro computer con-
trols the air flow direction so it may be different from
the display.
Operation mode includes automatic operation.
B. LEFT AND RIGHT DIRECTION
Adjusting air flow direction in the left and right direc-
tion (Refer to Fig. 1)
NOTE
Only make adjustments after you have stopped
the air flow direction swing in a position where
adjustments are possible. Your hand may get
caught if you attempt to make adjustments while
the unit is swinging.
Opera-
tion
mode
Cooling Heating
Opera-
tion
condition
When room
temperature is
lower than the
set tempera-
ture
When room
temperature is
higher than the
set temperature
At defrost opera-
tion
When operating continuously at
horizontal air flow direction
swing