Daikin FHQ50BVV1B Manuel d'instructions Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
English 3
Water may condensate and drip if the humidity
reaches 80% or if the drain exit gets clogged.
Do not place a burner or heater at a place
directly exposed to the wind from the air con-
ditioner.
Incomplete combustion of the burner or heater
may result.
Do not allow a child to mount on the outdoor
unit or avoid placing any object on it.
Falling or tumbling may result in injury.
Do not expose animals and plants directly to
the wind from the air conditioner.
Adverse influence to animals and plants may
result.
Do not wash the air conditioner with water.
Electric shock or fire may result.
Do not install the air conditioner at any place
where flammable gas may leak out.
If the gas leaks out and stays around the air con-
ditioner, a fire may break out.
Execute complete drain piping for perfect
drainage.
Incomplete piping may result in a water leakage.
The appliance is not intended for use by young
children or infirm persons without supervision.
Young children should be supervised to
ensure that they do not play with the appliance.
Consult with installation contractor for
cleaning the inside of the air conditioner.
Wrong cleaning may make the plastics parts
broken or cause failure of water leakage or elec-
tric shock.
Do not touch the air inlet or aluminium fin of
the air conditioner.
Otherwise, injury may be caused.
Do not place objects in direct proximity of the
outdoor unit and do not let leaves and other
debris accumulate around the unit.
Leaves are a hotbed for small animals which can
enter the unit. Once in the unit, such animals can
cause malfunctions, smoke or fire when making
contact with electrical parts.
If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the
air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING
3. OPERATION RANGE
OUTDOOR
UNIT
INDOOR
OUTDOOR
TEMPERA-
TURE
TEMPERA-
TURE
HUMID
ITY
R35 · 45 · 60
DB
18 to 33
80% or
below
DB
– 15 to 46
WB
12 to 24
RY35 · 45 · 60
DB
18 to 33
80% or
below
DB
– 5 to 46
WB
12 to 24
HEATING
D
B: Dry bulb temperature (°C)
WB: Wet bulb temperature (°C)
The setting temperature range of the remote con-
troller is 16°C to 32°C.
R71 · 100 · 125
RP71 · 100 · 125
REP71 · 100 · 125
DB
21 to 35
80% or
below
DB
– 15 to 46
WB
14 to 25
RY71 · 100 · 125
RYP71 · 100 · 125
RYEP71 · 100 · 125
DB
18 to 35
80% or
below
DB
– 5 to 46
WB
12 to 25
RZP71 · 100 · 125
DB
21 to 35
80% or
below
DB
– 5 to 50
WB
14 to 25
RQ71 · 100 · 125
DB
18 to 37
80% or
below
DB
– 5 to 46
WB
12 to 28
RR71 · 100 · 125
DB
18 to 37
80% or
below
DB
– 15 to 46
WB
12 to 28
RZQ71 · 100 ·
125 ·140
DB
18 to 37
80% or
below
DB
– 15 to 50
WB
12 to 28
RS50 · 60
RKS35 · 50 · 60
RXS35 · 50 · 60
DB
21 to 32
80% or
below
DB
– 10 to 46
WB
14 to 23
3MKS50
4MKS58 · 75 · 90
3MXS52 · 2MXS52
4MXS68 · 80
DB
21 to 32
80% or
below
DB
– 10 to 46
WB
14 to 23
RMKS112 · 140 · 160
RMXS112 · 140 · 160
DB
21 to 32
80% or
below
DB
– 5 to 46
WB
14 to 23
OUTDOOR
UNIT
INDOOR
TEMPERA-
TURE
OUTDOOR
TEMPERATURE
RY35 · 45 · 60 DB 15 to 27
DB – 9 to 21
WB – 10 to 15.5
RY71 · 100 · 125
RYP71 · 100 · 125
RYEP71 · 100 · 125
DB 15 to 27
DB
– 9 to 21
WB
– 10 to 15.5
RZP71 · 100 · 125
DB 15 to 27
DB – 14 to 21
WB – 15 to 15.5
RQ71 · 100 · 125 DB 10 to 27
DB – 9 to 21
WB – 10 to 15
RZQ71 · 100 ·
125 · 140
DB 10 to 27
DB – 19.5 to 21
WB – 20 to 15.5
RXS35 · 50 · 60 DB 10 to 30
DB – 14 to 24
WB – 15 to 18
3MXS52 · 2MXS52
4MXS68 · 80
DB 10 to 30
DB – 14 to 21
WB – 15 to 15.5
RMXS112 · 140 · 160
DB 10 to 30
DB – 14 to 21
WB – 15 to 15.5