Daikin BSVQ36PVJU Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Climatiseurs à système divisé Daikin BSVQ36PVJU. Daikin BSVQ36PVJU Installation manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 17
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
INSTALLATION MANUAL
III SYSTEM Air Conditioners
MODELS
BS unit
BSVQ36PVJU
BSVQ60PVJU
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
English
Français
Español
Vue de la page 0
1 2 3 4 5 6 ... 16 17

Résumé du contenu

Page 1 - III SYSTEM Air Conditioners

INSTALLATION MANUALIII SYSTEM Air ConditionersMODELS〈BS unit〉 BSVQ36PVJUBSVQ60PVJUREAD THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.KEEP THIS MANU

Page 2 - 1. SAFETY CONSIDERATIONS

9 EnglishExample of connection 1: When 1 indoor unit is connected downstream from the BS unitExample of connection 2: When there is a branch downstrea

Page 3

English 106-5 PIPING CONNECTIONFollow the connection example below and connect the site piping.6-6 PIPING INSULATION• After the gas leak inspection is

Page 4 - 2. BEFORE INSTALLATION

11 EnglishInsulation Installation Precautions1. Seal so that air cannot be in and out of the end.2. Do not over tighten the clamp so as to maintain th

Page 5 - 2-5 CHECK ITEM

English 127-2 EXAMPLE FOR THE WHOLE SYSTEM7-3 POWER CIRCUIT, SAFETY DEVICE AND CABLE REQUIREMENTS• A power circuit (Refer to Table 3) must be provided

Page 6

13 EnglishNOTE1. Connect cooling-dedicated air conditioners to terminals F1 and F2 (TO OUT/D UNIT) of the final BS unit.2. Use 2-core wire for the tra

Page 7 - 5. BS UNIT INSTALLATION

English 14NOTES• Use ring-type crimp style terminal for connections to the power terminal block. (Refer to Fig. 6)Also, insulate the crimped area by a

Page 8 - 6. REFRIGERANT PIPING WORK

15 English8. INITIAL SETTING• When the refrigerant piping and wire installation work is completed, make the following settings as required.1. Setting

Page 9 - 6-4 PIPING SIZE SELECTION

3P194121-3D EM07A062(0712) HTFS

Page 10

1 EnglishBSVQ36PVJUBSVQ60PVJUVRVIII SYSTEM Air ConditionersInstallation manualCONTENTS1 SAFETY CONSIDERATIONS...

Page 11 - 6-6 PIPING INSULATION

English 2• Do not ground units to water pipes, telephone wires or lightning rods because incomplete ground-ing could cause a severe shock hazard resul

Page 12 - 7. ELECTRIC WIRING WORK

3 English• Be very careful about product transportation.Some products use PP bands for packaging. Do not use any PP bands for a means of transportatio

Page 13 - 7-4 WIRING EXAMPLE

English 42-3 ACCESSORIESCheck the following accessories are included with your unit.NOTE• Do not throw away any of the accessories until installation

Page 14 - 7-5 WIRING CONNECTIONS

5 English3. SELECTING INSTALLATION SITESelect an installation site where the following conditions are satisfied and that meets with your customer’s ap

Page 15 - TO IN/D UNIT TO OUT/D UNIT

English 65. BS UNIT INSTALLATIONUse only accessories and parts which are of the designated specification when installing.(1) When necessary, use the f

Page 16 - 9. TEST OPERATION

7 English6. REFRIGERANT PIPING WORK• For instruction for installing piping between the outside unit and BS unit, selecting a refrigerant branch kit, a

Page 17 - (0712) HTFS

English 8• Use the following items for the refrigerant piping.Material: Jointless phosphor-deoxidized copper pipeSize: See “Example of connection” to

Commentaires sur ces manuels