Be sure to observe this instruction.
Be sure to establish an earth
connection.
Never attempt.
Read these Safety Precautions carefully to ensure correct installation.
This manual classifies the precautions into DANGER, WARNING and CAUTION. Be sure to follow all the
precautions below: they are all important for ensuring safety.
The following safety symbols are used throughout this manual:
After completing installation, test the unit to check for installation errors. Give the user adequate instructions
concerning the use and cleaning of the unit according to the Operation Manual.
DANGER
Refrigerant gas is heavier than air and replaces oxygen. A massive leak could lead to oxygen depletion, especially
in basements, and an asphyxiation hazard could occur leading to serious injury or death.
If the refrigerant gas leaks during installation, ventilate the area immediately.
Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device. Exposure to this gas could cause severe injury or death.
After completing the installation work, check that the refrigerant gas does not leak.
Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device. Exposure to this gas could cause severe injury or death.
Do not ground units to water pipes, telephone wires or lightning rods because incomplete grounding could cause a severe shock hazard
resulting in severe injury or death, and to gas pipes because a gas leak could result in an explosion which could lead to severe injury or death.
Safely dispose of the packing materials. Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries. Tear
apart and throw away plastic packaging bags so that children will not play with them. Children playing with plastic bags face the danger of death by suffocation.
Do not install unit in an area where flammable materials are present due to risk of explosion resulting in serious injury or death.
Do not ground units to telephone wires or lightning rods because lightning strikes could cause a severe shock hazard resulting in
severe injury or death, and to gas pipes because a gas leak could result in an explosion which could lead to severe injury or death.
WARNING
Installation should be left to the authorized dealer or another trained professional.
Improper installation may cause water leakage, electrical shock, fire, or equipment damage.
Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, fire or equipment damage.
Be sure to use the supplied or exact specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, fire or equipment damage.
Install the air conditioner on a solid base that is level and can support the weight of the unit.
An inadequate base or incomplete installation may cause injury or equipment damage in the event the unit falls off the base or comes loose.
Electrical work should be carried out in accordance with the installation manual and the national, state and local electrical wiring codes.
Insufficient capacity or incomplete electrical work may cause electrical shock, fire or equipment damage.
Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance. Follow all appropriate electrical codes.
Use the specified types of wires for electrical connections between the indoor and outdoor units. Follow all state and local electrical codes.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating, fire or equipment damage.
For wiring, use a wire or cable long enough to cover the entire distance with no splices if possible. Do not use an extension cord. Do not put other
loads on the power supply. Use a only a separate dedicated power circuit. (Failure to do so may cause abnormal heat, electric shock, fire or equipment damage.)
After connecting all wiring be sure to shape the cables so that they do not put undue stress on the electrical covers, panels or terminals.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock,fire or equipment damage.
When installing or relocating the system, be sure to keep the refrigerant circuit free from all substances other than the specified refrigerant (R410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise which may result in rupture, resulting in injury.)
Safety Precautions
DAIKIN AIR CONDITIONER
3P232733-1A M08B058A
Two-dimensional bar code
is a code for manufacturing.
WARNING
CAUTION
Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
Failure to follow any of CAUTION may in some cases result in grave consequences.
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - DAIKIN AIR CONDITIONER

Be sure to observe this instruction.Be sure to establish an earth connection.Never attempt.• Read these Safety Precautions carefully to ensure correct

Page 2 - Accessories

Safety PrecautionsAccessoriesPrecautions for Selecting the Location(A) Installation manual(B) Drain plug11CAUTION• Establish drain piping according to

Page 3 - Installation Guidelines

Precautions on InstallationOutdoor Unit Installation DrawingsInstallation Guidelines• Where a wall or other obstacle is in the path of outdoor unit’s

Page 4 - Outdoor Unit Installation (1)

Flare nut tightening torque Gas side Liquid side 3/8 inch 1/4 inch 24.1-29.4ft • Ibf 10.4-12.7ft • IbfValve cap tightening torque Gas side Liquid

Page 5 - Outdoor Unit Installation (2)

Outdoor Unit Installation (2)*1. Pipe length vs. vacuum pump run time*2. If the vacuum pressure gauge pointer swings back, refrigerant may have water

Page 6 - Pump Down Operation

Outdoor Unit Installation (3)7. Refrigerant Piping Work7-1 Cautions on Pipe Handling1)Protect the open end of the pipe against dust and moisture.2)All

Page 7 - Good Wrong

Wiring• Do not turn ON the safety breaker until all work is completed.1)Strip the insulation from the wire (3/4 inch).2) Connect the connection wires

Page 8 - Run Test and Final Check

Run Test and Final Check1. Trial Operation and Testing.1-1 Measure the supply voltage and make sure that it falls in the specified range.1-2 Trial ope