SPECIFICATIONS
29
INDOOR UNITS
Slim Ceiling Mounted Duct Type (700 mm width type)
Slim Ceiling Mounted Duct Type (900/1,100 mm width type)
Galvanised steel plate
7,800
2,000
9,900
2,500
12,600
3,200
2.2
133/120/106 133/120/106 133/120/106
33/31/29 33/31/29 33/31/29
8,500
2,200
10,900
2,800
13,600
3,400
Btu/h
2.5 3.2 4.0kW
kcal/h
Heating capacity
1-phase, 220-240 V/220 V, 50/60 HzPower supply
200
X
700
X
620
23
6.4
12.7
200
X
700
X
620
23
6.4
12.7
200
X
700
X
620
23
6.4
12.7
51 51 51dB(A)Sound power (HH)
2.8 3.6
2.3 2.9 3.7
VP20 (External Dia, 26/Internal Dia, 20)
30-10
1
MODEL
FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE
0.067 0.067 0.070
0.086 0.086 0.089
8.0/7.2/6.4 8.0/7.2/6.4 8.0/7.2/6.4
Cooling capacity
kW
(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Dimensions (H
X
W
X
D) mm
Machine weight kg
Piping
connections
Drain
Liquid (Flare)
Gas (Flare)
mm
Cooling
Heating
Airflow rate (HH/H/L)
/s
m
3
/min
dB(A)
Casing
Sound level (HH/H/L)
PaExternal static pressure
3
2
Power
consumption
kW
Galvanised steel plate
16,000
4,000
19,800
5,000
24,900
6,300
17,100
4,300
21,500
5,400
27,300
6,900
Btu/h
5.0 6.3 8.0kW
kcal/h
175/158/141 208/183/166 275/241/216
34/32/30 35/33/31 36/34/32
Heating capacity
1-phase, 220-240 V/220 V, 50/60 HzPower supply
200
X
900
X
620
27
6.4
12.7
200
X
900
X
620
28
6.4
12.7
200
X
1,100
X
620
31
9.5
15.9
52 53 54dB(A)Sound power (HH)
4.5 5.6 7.1
4.7 5.8 7.3
VP20 (External Dia, 26/Internal Dia, 20)
44-15
1
MODEL
FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE
0.160 0.165 0.181
0.147 0.152 0.168
10.5/9.5/8.5 12.5/11.0/10.0 16.5/14.5/13.0
Cooling capacity
kW
(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Dimensions (H
X
W
X
D) mm
Machine weight kg
Piping
connections
Drain
Liquid (Flare)
Gas (Flare)
mm
Casing
Cooling
Heating
Power
consumption
kW
Airflow rate (HH/H/L)
/s
m
3
/min
dB(A)Sound level (HH/H/L)
PaExternal static pressure
3
2
1:
External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard".(Factory setting is 10 Pa for
FXDQ-PB models and 15 Pa for FXDQ-NB models.)
2: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be
obtained by adding 5 dB(A).
3: Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.
Note: Specifications are based on the following conditions;
•Cooling: (*1) Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
(*2) Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.