Energy efficiency and quiet operation
Outdoor units use Daikin’s unique scroll compressor for energy efficiency
and quiet operation.
MAIN FEATURES
High COP during both cooling and
heating operations
Quiet operation provides
luxurious comfort
Quietness is yet another important feature
of Daikin’s VRVIII-S system. To reduce
noise and realise comfortable operation,
latest technologies and features are
applied to the outdoor units.
One of the top features of the VRVIII-S is
its energy efficiency. It achieves high COP
during cooling and heating operations by
utilising Daikin’s unique scroll compressor.
Above values are based on the following nominal conditions:
• 2 built-in units are connected (4 class (11.2 kW): FXSYQ50M x 2; 5 class
(14 kW): FXSYQ63M x 2; and 6 class (15.5 kW): FXSYQ63M + FXSYQ80M.)
Cooling: Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
VRVII-S
Previous model
RXYMQ-MV4A
VRVII-S
Previous model
RXYMQ-MV4A
Lower operation sound
is achieved!
Cooling
Heating
2.94
3.62
2.81
3.45
3.73
3.58
3.03
2.82
Cooling
50
51
53
4 class (11.2 kW)
5 class (14 kW)
6 class (15.5 kW)
5 class (14 kW)
3.15
3.07
4 class (11.2 kW)
6 class (15.5 kW)
5 class (14 kW)
3.37
3.27
4 class (11.2 kW)
6 class (15.5 kW)
Heating
52
53
55
53
54
56
51
52
54
4 class (11.2 kW)
5 class (14 kW)
6 class (15.5 kW)
5
Nighttime quiet operation function
Set on the outdoor PCB. Time of maximum temperature is
memorised. The low operating mode will initiate 8 hours*
1
after
the peak temperature in the daytime, and normal operation will
resume 10 hours*
2
after that. The operation sound level for the
night mode can be selected from 47 dB(A) (Step 1), 44 dB(A)
(Step 2) and 41 dB(A) (Step 3).
Automatic mode
Mode 1.
Automatic mode
Mode 1.
Starting time and ending time can be input. (An external control
adaptor for outdoor unit, DTA104A53/61/62, and a locally
obtained timer are necessary.)
Manual mode
Mode 2.
Combinations of modes 1 and 2 can be used depending on
your needs.
Combined mode
Mode 3.
*1. Initial setting. Can be selected from 6, 8 and 10 hours.
*2. Initial setting. Can be selected from 8, 9 and 10 hours.
Note:
• This function is available in setting at site.
• The relationship of outdoor temperature (load) and time shown in the
graph is just an example.
Peak in outdoor temperature
Capacity %
8 hrs 10 hrs
Operation sound dB(A)
47
8:00 12:00 16:00 20:00 0:00 4:00 8:00
50
100
50
0
Load %
Night mode endsNight mode starts Night mode endsNight mode starts
Night Mode
44
41
(Initial setting)(Initial setting)
Step 1 max. - 3 dB(A)
( 4 class/11.2 kW)
Step 2 max. - 6 dB(A)
( 4 class/11.2 kW)
Step 3 max. - 9 dB(A)
( 4 class/11.2 kW)
Step 1: 47 dB(A)
Step 2: 44 dB(A)
Step 3: 41 dB(A)
Operation sound level selectable
from 3 steps for the night mode
The capacity reduction rate differs depending on the operation sound level
step selected.
-1dB(A)
-1dB(A)
-1dB(A)
-1dB(A)
-1dB(A)
-1dB(A)
1 dB(A) reduced
in
each model!
High COP
achieved
in all ranges!