Daikin FH(Y)125BVE Spécifications

Naviguer en ligne ou télécharger Spécifications pour Climatiseurs à système divisé Daikin FH(Y)125BVE. Daikin FH(Y)125BVE Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
English
Español
SPLIT SYSTEM Air Conditioner
OPERATION MANUAL
MODELS
(Ceiling suspension type)
FH(Y)35BVE FH(Y)71BVE
FH(Y)50BVE FH(Y)100BVE
FH(Y)60BVE FH(Y)125BVE
00_CV_3P170549-4.fm Page 1 Friday, December 9, 2005 9:13 PM
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - OPERATION MANUAL

EnglishEspañolSPLIT SYSTEM Air ConditionerOPERATION MANUALMODELS(Ceiling suspension type)FH(Y)35BVE FH(Y)71BVEFH(Y)50BVE FH(Y)100BVEFH(Y)60BVE FH(Y)12

Page 2

7 EnglishMOVEMENT OF THE AIR FLOW FLAPFor the following conditions, micro computer con-trols the air flow direction so it may be different from the di

Page 3

English 8• Never place objects near the air inlet and the air outlet of the unit. It may cause deterioration in the effect or stop in the operation.•T

Page 4 - 1. WHAT TO DO BEFORE OPERA

9 English4. Fix the air filter.Set the hatch of the air filter to the fook of the suction grille, and fix the air filter.(Refer to Fig. 5)5. Close th

Page 5 - 2. SAFETY CONSIDERATIONS

English 10The following symptoms do not indicate air condi-tioner malfunctionI. THE SYSTEM DOES NOT OPERATE• The system does not restart immediately a

Page 6 - 3. OPERATION RANGE

11 EnglishI. If one of the following malfunctions occurs, take the measures shown below and contact your Daikin dealer.The system must be repaired by

Page 7 - Regarding wiring

English 12(These specifications are in compliance with SASO386.)11. SPECIFICATIONS INDOOR UNITOUTDOOR UNITRATED VOLTAGERATED FREQUENCYFH50BVER50GVAL22

Page 8 - 6. OPERATION PROCEDURE

3P170549-4 EM00A035A(0602) HT00_CV_3P170549-4.fm Page 4 Friday, December 9, 2005 9:13 PM

Page 9

Thank you for purchasing this Daikin air condi-tioner. Carefully read this operation manual before using the air conditioner. It will tell you how to

Page 10 - 7. OPTIMUM OPERATION

[1]1342 00_CV_3P170549-4.fm Page 2 Friday, December 9, 2005 9:13 PM

Page 11 - (FOR SERVICE PERSONNEL)

1 EnglishCONTENTSILLUSTRATION... [1]1. WHAT TO DO BEFORE OPERATION... 12. SAFETY CONSIDERATIONS

Page 12

English 2We recommend that you read this instruction man-ual carefully before use to gain full advantage of the function of the air conditioner, and t

Page 13 - CONDITIONER

3 EnglishNeither place a flammable spray bottle near the air conditioner nor perform spraying.Doing so may result in a fire.To clean the air condition

Page 14 - 10. TROUBLE SHOOTING

English 4D B: Dry bulb temperatureWB: Wet bulb temperatureThe setting temperature range of the remote con-troller is 16°C to 32°C.Regarding places for

Page 15 - 11. SPECIFICATIONS

5 English8DISPLAY “ ” (SET TEMPERATURE)This display shows the set temperature.9DISPLAY “ ” (FAN SPEED)This display shows the set fan speed.10DISPLAY “

Page 16 - 3P170549-4 EM00A035A

English 6[EXPLANATION OF HEATING OPERATION]DEFROST OPERATION• As the frost on the coil of an outdoor unit increase, heating effect decreases and the s

Commentaires sur ces manuels

Pas de commentaire