INSTALLATION MANUALR410A Split SeriesModels FTYN25DV3B FTN25DV3BFTYN35DV3B FTN35DV3BFTYN25DAV3B FTN25DAV3BFTYN35DAV3B FTN35DAV3BFrançaisNederlandsEspa
English 85.Thermistor cable. The thermistor cable is secured to the indoor unit.If performing the wiring after removing the thermistor cable, follow
9 EnglishOutdoor Unit1.Installing outdoor unit.• For outdoor unit installation, see Choosing a Site and Indoor/Outdoor Unit Installation Drawings.2.
English 104.Purging air and checking gas leakage.• When piping work is completed, it is necessary to purge the air and check for gas leakage. WARNING
11 EnglishOutdoor Unit 5.Pump down operation.In order to protect the environment, be sure to pump down when relocating or disposing of the unit.1) Re
English 12Observe the notes mentioned below when wiring to the power supply terminal board. Precautions to be taken for power supply wiring. (Use a r
13 EnglishOutdoor Unit 7.Drain work. 1) Use drain plug for drainage.2) If the drain port is covered by a mounting base or floor surface, place addi
(0511) HT3P147083-2F M05B07300_CV_3P147083-2F.fm Page 2 Wednesday, September 28, 2005 10:34 AM
Umeda Center Bldg., 4-12, Nakazaki-Nishi 2-chome,Kita-ku, Osaka, 530-8323 Japan 2SB63475-6CFTYN25DV3B, FTYN35DV3B, FTYN25DAV3B, FTYN35DAV3B, FTN25DV3B
1 EnglishSafety Precautions• Read these Safety Precautions carefully to ensure correct installation.• This manual classifies the precautions into WAR
English 2Accessories – , *1 The thermistor cable is attached to the indoor unit.Choosing a Site• Before choosing the installation site, obtai
3 EnglishIndoor/Outdoor Unit Installation Drawings Titanium ApatitePhotocatalyticAir-Purifying FilterFilter frameAir filterTa bDM3 × 20LWireless remo
English 4Outdoor Unit Installation Guidelines• Where a wall or other obstacle is in the path of outdoor unit’s intake or exhaust airflow, follow the
5 EnglishIndoor Unit 1.Installing the mounting plate.• The mounting plate should be installed on a wall which can support the weight of the indoor un
English 63.Installing indoor unit.3-1. Right-side, right-back, or right-bottom piping.1) Attach the drain hose to the underside of the refrigerant pi
7 EnglishIndoor Unit Note:1) Wrap the refrigerant pipes and drain hose together with insulation tape as right figure, in case of setting the drain ho