FUQ-BU4-way Blow CeilingSuspended Cassettetechnical data SplitSky Airair conditioning systems
5Wiring diagrams3D043746FUQ71∼125BUV1BA1P Printed circuit boardC1R Capacitor (M1F)HAP Light emitting diode (service monitor green)KAR Magnetic relay (
6Sound level6-1Sound level dataOctave band sound pressure levelOctave band sound pressure levelOctave band center frequency (Hz) Octave band center fr
7Air flow patternsFUQ71BUV1BCooling - air velocity distribution4-way discharge air flow direction: horizontalFUQ71BUV1BCooling - air temperature distr
FUQ71BUV1BHeating - air velocity distribution4-way discharge, air flow direction: downFUQ71BUV1BHeating - air temperature distribution4-way discharge,
FUQ100BUV1BCooling - air velocity distribution4-way discharge air flow direction: horizontalFUQ100BUV1BCooling - air temperature distribution4-way dis
FUQ100BUV1BHeating - air velocity distribution4-way discharge, air flow direction: downFUQ100BUV1BHeating - air temperature distribution4-way discharg
FUQ125BUV1BCooling - air velocity distribution4-way discharge air flow direction: horizontalFUQ125BUV1BCooling - air temperature distribution4-way dis
FUQ125BUV1BHeating - air velocity distribution4-way discharge, air flow direction: downFUQ125BUV1BHeating - air temperature distribution4-way discharg
8Accessories8-1Standard accessoriesNamej1Drain hosej2Clampj3Washer for hanging bracketj4ClampQuantity 1 pc. 1 pc. 8 pcs. 6 pcs.ShapeNamej5Washer fixin
8Accessories8-2Optional accessoriesName of option FUQ-BUV1B71 100 125Sealing member of air discharge outlet KDBHJ49F80 KDBHJ49F140Decoration panel for
Split - Sky AirEEDE05-1/3 • 05/2005Prepared in Belgium by Goekint GraphicsZandvoordestraat 300B - 8400 Ostend BelgiumSpecifications are subject to cha
9Control systems9-1Wired remote control6.5 x 9 (Round end slit)Cover openCover closed5 x 7 (Round end slit)HoleJ55 x 10 (Round end slit)3TW23651-2BRC1
10Safety device settingsFUQ71-100-125BUV1BModel Safety devices FUQ71BUV1B FUQ100BUV1B FUQ125BUV1BFUQ-BUV1BFuse −−−Fan motor thermal fuse (°C) −−−Fan m
TABLE OF CONTENTSFUQ-BU1 Features ... 22 Specifications...
1Features+ Ideal for refurbishment+ Leaves maximum floor and wall space for furniture, decorationand fittings+ Air can be discharged in any of four di
2SpecificationsNOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FUQ71BUV1B FUQ100BUV1B FUQ125BUV1BNOMINAL INPUT Cooling kW 0.180 0
TECHNICAL SPECIFICATIONSINDOOR UNITS FUQ71BUV1B FUQ100BUV1B FUQ125BUV1BDIMENSIONS Unit H mm 165 230 230W mm 895 895 895D mm 895 895 895WEIGHT Unit kg
ELECTRICAL SPECIFICATIONSFor indoor units only: FUQ71BUV1B FUQ100BUV1B FUQ125BUV1BCURRENT Nominal running currentcoolingASee chapter RR-B7, RQ-B7, RZQ
3Dimensional drawingsFUQ71BUV1B1Liquid pipe connection - J9.5 flare2 Gas pipe connection J15.9 flare3 Drain pipe connection V.P.204 Air outlet5 Air su
4Piping diagramsO Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipeIndoor heat exchangerField piping
Commentaires sur ces manuels