Daikin Altherma Large Monobloc Spécifications Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
10
3.TECHNICALLY
SUPER PERFORMANCE THANKS
TO THE INVERTER PRINCIPLE
The coefficient of performance (COP) of the Daikin
Altherma
heat pump is also largely attributable to
the Daikin inverter principle. An integrated frequency-
converter adjusts the rotational speed of the compressor
to suit the heating demand. Therefore, the system
seldom operates at full capacity and your customer only
pays for the energy which they actually need.
HEAT EXCHANGER
ANTI-CORROSION TREATMENT
As standard, the heat exchanger in the outdoor unit is
provided with an anti-corrosion treatment. This treat-
ment guarantees and noticeably increases the resistance
against acid rain and salt corrosion.
Typical Daikin heat
exchanger
Aluminium
Hydrophilic layer
Corrosion-resistant acrylate
resin
HIGH EFFICIENCY COMPRESSORS:
1 - DAIKIN ALTHERMA
TM
SPLIT TYPE AIR-TO-WATER HEAT PUMP
THE OUTDOOR UNIT
Compact, weather-resistant and easy to install >
Contains an inverter controlled compressor for energy efficiency and precise temperature regulation >
Heat pump operation range: heating and domestic hot water to -4°F (-20°C) outside temperature >
The scroll-compressors are designed as a compact, robust, low-noise device to guarantee optimal
operational reliability (no valves and built-in swing-link coupling) and efficiency (through a low initial
flow and a constant compression ratio). It uses Pulse Width Modulation (PWM) Technology.
Slow
start
Temperature remains stable
Temperature / Power input
Time
Set
temp.
System
with
Inverter
System
without
Inverter
Heating operation:
The swing-compressors have been setting trends in the area of energy efficient performance for the
past 10 years (leaks and friction are basically non-existent). The design of the swing compressor reduces
friction during operation for smoother and quieter rotation with less vibration resulting in a more durable
compressor. It also minimizes the leakage of refrigerant gas during compression. The result is a system
that operates quietly and efficiently. It uses Pulse Amplitude Modulation (PAM) Technology. The PAM
Control reduces energy loss by controlling how often the converter switches on and off.
Vue de la page 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 31 32

Commentaires sur ces manuels

Pas de commentaire