2. Application “heating” and “production of domestic hot water”
The temperature in each room is regulated by a valve on every water circuit. Hot water for domestic use is delivered
by the domestic hot water tank connected to the indoor unit.
Outdoor unit
1.
Hydrobox2.
Heat exchanger3.
Pump4.
Valve5.
Manifold (field supply)6.
Valve7.
FHL1…3 (Under) floor heating loop
(field supply)
T Room thermostat
Outdoor unit
1.
Hydrobox2.
Heat exchanger3.
Pump4.
Valve5.
Manifold (field supply)6.
Valve7.
Motorized 3-way valve8.
Pressure relief valve9.
Booster heater10.
Heat exchanger spiral11.
Tank for domestic hot water12.
FHL1…3 (Under) floor heating loop
(field supply)
T 1…3 Individual room thermostat
1. Application “heating only” with a room thermostat connected to the indoor unit