Daikin J Series Manuel de service Page 144

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 162
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 143
Si04-115 For RK25J, RK35J, RX25J, RX35J
Removal Procedure 135
2
The compressor’s
mounting nut to be
removed is one piece.
Warning
Since it may happen that
refrigeration oil in the
compressor will catch fire,
prepare wet cloth so as to
extinguish
fire quickly.
Warning!
Ventilate when refrigerant
leaks during the work.(If
refrigerant contacts fire, it will
cause to arise toxic gas).
Caution
Be careful about pipes and so
on, which were heated up by a
gas brazing machine, so as
not to get burnt on your
hands.
"
Pay attention so that the
heat exchanger’s fins will not
be burnt.
3
Remove the nut by
means of an open-end
wrench.
"
Begin your work after
recognizing complete
empty of refrigerant in the
refrigerant circuit.
"
Be sure to apply nitrogen’s
permutation when heating
up the brazing part.
1
Remove the brazing
part on the compressor
discharge side.
2
Heat up the brazing
part on the compressor
suction part and then
remove it.
3
Lift the compressor and
remove it.
Step Procedure Points
Vue de la page 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 161 162

Commentaires sur ces manuels

Pas de commentaire